BTU Calculator

Enter the room dimensions, insulation quality, sun exposure, and how many people use it. The calculator estimates the cooling load in BTU per hour and kilowatts, the equivalent in tons of cooling, and the heating capacity for your design temperature difference. With the defaults the room needs about 4,436 BTU/h of cooling, or 1.3 kW.

Updated 2026-11-18 Editorial estimate Calccc Editorial Team Free · No sign-up
m
m
m

Each person adds roughly 100 W of sensible heat.

°C

Indoor target minus the coldest outside design temperature. 25 °C suits a mild winter climate.

Scenarios A/BSave two input sets and compare the results. Stored only in this browser.
AEmpty
BEmpty

Your inputs stay in this browser. No account, no uploads.

Professional worksheet

Detailed schedule & assumptions

Inputs used, method, sensitivity, and any year-by-year table. The summary above stays compact; the audit lives here.

Professional worksheet

Inputs, scope, and sensitivity

Inputs used

Method and scope

Result audit

MetricValue

What this calculator does

Air conditioners and heaters are sold by capacity, and capacity has to match the room. Too small and the unit runs continuously without reaching the set point; too large and a cooling unit short-cycles, leaving the room cold and clammy while wasting energy. The starting point is the room's heat gain, which is driven by floor area, ceiling height, insulation, window area, sun exposure, and the number of people inside. This calculator uses a rule-of-thumb load: about 55 watts per square metre, scaled by an insulation multiplier and a sun-exposure multiplier, plus 100 watts for each occupant. Heating is estimated from the same area at a stated design temperature difference. It is a single-room estimate, not a substitute for a room-by-room heat-loss calculation such as Manual J, which accounts for wall construction, glazing, air leakage, and duct losses.

How to use it

  1. Measure the room's length and width in metres and its ceiling height.
  2. Pick the insulation quality that best matches the walls, roof, and glazing.
  3. Choose the sun exposure: shaded, average, or sunny with large windows.
  4. Enter how many people normally occupy the room.
  5. Set the design temperature difference for your climate, then use the result as a sizing starting point.

How it works

Cooling load (W) = floor area × 55 W/m² × insulation factor × sun factor + occupants × 100 W. Heating load (W) = floor area × 60 W/m² × insulation factor × (design ΔT ÷ 30). In the default case: 20.0 m² × 55 × 1.00 × 1.00 + 2 × 100 = 1,300 W, which is 4,436 BTU/h.

Example calculations

Example 1: A 20 m² living room

Five by four metres with a 2.5 m ceiling, average insulation, average sun, and two people needs 1,300 W of cooling, or 4,436 BTU/h and 1.3 kW. Heating for a 25 °C design difference is 1.0 kW, or 3,412 BTU/h.

Example 2: A large, sunny, poorly insulated room

Eight by six metres with a 2.7 m ceiling, poor insulation, direct sun, and four occupants needs 4,096 W, or 13,976 BTU/h and 1.16 tons of cooling. Heating rises to 3.0 kW. The same floor area with better insulation would need far less.

Example 3: A small, shaded, well-insulated room

Four by three and a half metres with good insulation, shade, one occupant, and a 20 °C design difference needs only 654 W, or 2,233 BTU/h. Heating is 0.4 kW. Insulation and shade can cut the load by more than half compared with the poorly insulated case.

What the result means

The cooling figure is the heat the room gains on a design day, so the equipment should be able to remove at least that much. Sizing slightly above the estimate is normal, but oversizing a cooling unit is a real problem: it cools the air before it removes humidity, which leaves the room feeling damp. Ducted systems and multi-room plans need a load calculation for each room, because a single number for the whole house will not balance the airflow. The heating estimate is even more sensitive to climate: the design temperature difference for a mild coastal winter is nothing like an inland cold snap, and the number entered changes the result proportionally. Use the estimate to shortlist equipment, then have a contractor confirm the load and the duct or radiator capacity.

Common mistakes

  • Sizing from floor area alone and ignoring ceiling height and window area.
  • Using the summer design temperature instead of the difference between indoor and outdoor design conditions.
  • Oversizing the air conditioner, which causes short cycling and poor humidity control.
  • Forgetting occupants, cooking, and equipment heat gain in a busy room.
  • Assuming a room's insulation is better than it is because the house is new.
  • Treating a rule-of-thumb estimate as a substitute for a room-by-room load calculation.

Assumptions and limits

  • The room is a single enclosed space with typical residential construction.
  • Insulation and sun factors in the model reasonably match the room.
  • Each occupant adds about 100 W of sensible heat.
  • The design temperature difference reflects the local climate.
  • No unusual internal gains from cooking, servers, or machinery are included.

Frequently asked questions

How many BTU do I need per square metre?

This model starts at about 55 W per square metre, which is roughly 188 BTU/h per square metre, then adjusts for insulation and sun. Real loads vary widely with glazing, ceiling height, and climate, so treat it as a starting point.

What is a ton of cooling?

One ton of cooling is 12,000 BTU per hour, a unit that comes from the heat needed to melt a ton of ice a day. A small bedroom might need a third of a ton, while a large living area can need more than one.

Is it better to oversize an air conditioner?

No. An oversized unit cools the air quickly and shuts off before it removes much humidity, leaving the room cold and clammy and wearing the compressor with frequent starts. Slight oversizing is safer than a large margin.

Why does ceiling height matter?

Because the volume of air, not just the floor area, determines how much heat the space holds and how much air has to be conditioned. A 3 m ceiling holds 20% more air than a 2.5 m ceiling over the same floor.

Do I use the same number for heating and cooling?

No. Cooling depends on heat gain from sun, people, and equipment, while heating depends on heat loss through the envelope and the design temperature difference. The two numbers are calculated separately here.

Can I use this for a whole house?

Only as a rough first estimate. A whole-house system needs a room-by-room load calculation and duct design, because orientation, glazing, and occupancy differ from room to room.

Sources

This is an educational sizing estimate, not an engineering load calculation. Real equipment sizing depends on a room-by-room heat-loss and heat-gain analysis, local climate data, duct design, and building code. Have a qualified contractor verify capacity before purchase or installation.

2026 update

How to use the professional output

This page is not just a formula box. The result is designed to be checked, compared, and taken away.

  • Professional worksheet. The result includes the inputs used, the method and scope, and a one-variable sensitivity check for finance calculators.
  • A/B scenarios. Save two input sets in the browser and compare the primary, secondary, and breakdown figures side by side.
  • Print / PDF and CSV. Print a branded worksheet, or export the year-by-year table when the calculator produces one.

The formulas and assumptions above still govern the number. The worksheet makes the estimate auditable; it does not make it a lender quote, tax return, or personalized advice.

Calccc Editorial Team · Updated 2026-11-18

Prepared by Calccc Editorial Team as an educational estimate. This page is not a licensed professional review and is not financial, medical, legal, or tax advice.

Editorial estimate prepared by the Calccc Editorial Team; not a licensed professional review.