Lighting Calculator

Enter the room size, pick the room and task, and set the lumens per fitting. The calculator multiplies floor area by the target illuminance, divides by the usable lumens from each fitting, and rounds up to whole fittings. It also reports the achieved lux, an even spacing grid, and the estimated electrical load. The default living room needs 4 fittings.

Updated 2026-11-18 Editorial estimate Calccc Editorial Team Free · No sign-up
m
m

Target maintained illuminance on the working plane.

lm

The output printed on the lamp or fitting, for example 800 lm for a typical LED downlight.

Advanced options

Share of light that reaches the working plane. Lower it for dark rooms with high ceilings.

Allowance for dust and lamp ageing. 0.8 is a common design value.

lm/W

Used only for the electrical load estimate. Modern LEDs are around 90-130 lm/W.

Scenarios A/BSave two input sets and compare the results. Stored only in this browser.
AEmpty
BEmpty

Your inputs stay in this browser. No account, no uploads.

Professional worksheet

Detailed schedule & assumptions

Inputs used, method, sensitivity, and any year-by-year table. The summary above stays compact; the audit lives here.

Professional worksheet

Inputs, scope, and sensitivity

Inputs used

Advanced inputs used

Method and scope

Result audit

MetricValue

What this calculator does

Lighting a room well is a design problem with an arithmetic core. Each task needs a certain amount of light on the surface where the work happens, measured in lux. A hallway is comfortable at about 100 lux, a living room at 150, a kitchen worktop at 300, and a desk at 400 or more. Multiply the target lux by the floor area to get the total lumens the room needs, then divide by the useful lumens each fitting delivers. Useful is smaller than the label because some light is lost in the fitting and the room, and because dust and ageing reduce output over time. That is what the utilisation and maintenance factors account for. The result is a count and a spacing grid, not a lighting design: beam angles, wall colour, ceiling height, and the position of the task decide whether the room feels bright or gloomy even when the numbers are right.

How to use it

  1. Measure the room's length and width in metres.
  2. Pick the room type that matches the task, which sets the target illuminance.
  3. Enter the lumens printed on the fitting or lamp you plan to use.
  4. Leave the utilisation and maintenance factors at their defaults unless the room is unusually dark or the ceiling is high.
  5. Check the spacing grid against the ceiling layout and adjust the fitting count or output.

How it works

Fittings = ceiling(floor area × target lux ÷ (lumens per fitting × utilisation factor × maintenance factor)). In the default case: 12.0 m² × 150 lux = 1,800 lm required; 800 lm × 0.80 × 0.80 = 512 useful lm per fitting; 1,800 ÷ 512 = 4 fittings.

Example calculations

Example 1: A 12 m² living room

Four by three metres at 150 lux needs 1,800 lumens. With 800 lm fittings that deliver 512 useful lumens each, 4 fittings are required. That gives 171 lux and a spacing grid of about 1.73 m.

Example 2: A 20 m² kitchen worktop

Five by four metres at 300 lux needs 6,000 lumens, so 12 of the same 800 lm fittings are needed and the achieved level is 307 lux. The spacing grid is about 1.29 m, and the estimated load is 96 W.

Example 3: A 9 m² home office

Three by three metres at 400 lux needs 3,600 lumens. Brighter 1,200 lm fittings deliver 768 useful lumens each, so 5 are enough and the achieved level is 427 lux. Fewer, brighter fittings mean wider spacing and fewer ceiling holes.

What the result means

The count is a floor, not a target. Layering matters more than raw output: a ceiling fitting that lights the whole room plus a task lamp at the desk usually feels better than doubling the ceiling fittings. Colour temperature also changes the impression, with warmer light reading as cosy and cooler light reading as clinical, and high colour rendering helps in kitchens and bathrooms. Dimmers give back the flexibility that a fixed count removes. The maintenance factor is worth taking seriously in a kitchen or a workshop, where grease and dust cut output faster than the default assumes. And the spacing figure is only a guide: fittings near a wall should be about half a spacing from it, not a full one.

Common mistakes

  • Using the room area but forgetting that the task surface, not the floor, is where lux is measured.
  • Ignoring the utilisation and maintenance factors and assuming every lumen reaches the surface.
  • Buying fittings by wattage instead of lumens now that LED efficacy varies so much.
  • Placing fittings in a grid that ignores the worktop or desk position.
  • Forgetting that dark walls and high ceilings absorb light and reduce the achieved level.
  • Over-lighting a small room and then having no dimming control.

Assumptions and limits

  • The room is a simple rectangle with a flat ceiling at a normal domestic height.
  • Fittings are evenly distributed across the ceiling.
  • Utilisation and maintenance factors reasonably match the room and fitting type.
  • Lumens per fitting are the delivered output, not the raw LED lumen figure.
  • The target lux comes from typical residential guidance, not a task-specific standard.

Frequently asked questions

How many lux does a room need?

Common residential targets are about 100 lux for bedrooms and hallways, 150 for living rooms, 200 for bathrooms, 300 for kitchen worktops, and 400 for a desk. Commercial and task-specific standards can be higher.

What is a utilisation factor?

The share of the light leaving a fitting that actually reaches the working plane. It depends on the fitting's optics, the room proportions, and the surface reflectances. 0.8 is a reasonable domestic default.

Why is a maintenance factor used?

Because lamps dim with age and surfaces collect dust, the installed output falls over time. Designing with a factor of about 0.8 means the room still meets the target when the fittings are older and dirty.

Should I use watts or lumens to compare fittings?

Lumens. Watts tell you how much electricity a fitting uses, not how much light it produces. Modern LEDs vary widely in efficacy, so two 10 W fittings can differ by hundreds of lumens.

Can I use fewer, brighter fittings?

Yes, if the beam angles and spacing still cover the room evenly. Fewer bright fittings can create shadows and glare, so check the spacing and consider a mix of ambient and task lighting.

Does ceiling height change the answer?

It changes the achieved lux and the spacing. Higher ceilings spread light over a larger area and reduce the level at the working plane, so the utilisation factor should be lowered or the fitting output increased.

Sources

This is an educational lighting estimate, not a lighting design or electrical plan. A qualified electrician must confirm circuits, earthing, and installation requirements, and a lighting designer should verify levels for task-critical spaces.

2026 update

How to use the professional output

This page is not just a formula box. The result is designed to be checked, compared, and taken away.

  • Professional worksheet. The result includes the inputs used, the method and scope, and a one-variable sensitivity check for finance calculators.
  • A/B scenarios. Save two input sets in the browser and compare the primary, secondary, and breakdown figures side by side.
  • Print / PDF and CSV. Print a branded worksheet, or export the year-by-year table when the calculator produces one.

The formulas and assumptions above still govern the number. The worksheet makes the estimate auditable; it does not make it a lender quote, tax return, or personalized advice.

Calccc Editorial Team · Updated 2026-11-18

Prepared by Calccc Editorial Team as an educational estimate. This page is not a licensed professional review and is not financial, medical, legal, or tax advice.

Editorial estimate prepared by the Calccc Editorial Team; not a licensed professional review.