Skip to content

French Drain Calculator

Enter the drain length, trench width and depth, gravel fill, pipe diameter, and fabric overlap. The calculator gives trench volume, gravel volume and weight, pipe length, and fabric area. A 20 m run at 0.4 m wide and 0.6 m deep needs about 3.68 m³ of gravel, or 5.89 tonnes.

Updated 2026-11-19 Editorial estimate Calccc Editorial Team Free · No sign-up
m
m
m
%

Share of the trench volume filled with gravel after the pipe is placed.

mm
Advanced options
t/m³
m
Scenarios A/BSave two input sets and compare the results. Stored only in this browser.
AEmpty
BEmpty

Your inputs stay in this browser. No account, no uploads.

Professional worksheet

Detailed schedule & assumptions

Inputs used, method, sensitivity, and any year-by-year table. The summary above stays compact; the audit lives here.

Professional worksheet

Inputs, scope, and sensitivity

Inputs used

Advanced inputs used

Method and scope

Result audit

MetricValue

What this calculator does

A French drain is a trench filled with gravel and a perforated pipe that collects surface or groundwater and carries it away. The materials are simple, but the quantities add up quickly, and a shortfall in gravel or fabric in the middle of a dig is expensive. This calculator estimates the trench volume, subtracts the space taken by the pipe, applies the gravel fill percentage, and converts the gravel to tonnes using the density you enter. It also estimates the filter fabric width and area, including an overlap allowance. The result is a material take-off, not a drainage design: the fall, outlet, soil type, and local rules still need to be right for the drain to work.

How to use it

  1. Measure the length of the drain run in metres.
  2. Enter the trench width and depth you plan to dig.
  3. Choose the gravel fill percentage for the trench.
  4. Enter the perforated pipe diameter.
  5. Adjust the gravel density and fabric overlap if your supplier's figures differ.
  6. Add the outlet, clean-outs, and any fall to the design before ordering.

How it works

Trench volume = length × width × depth. Pipe volume = π × (pipe diameter in metres / 2)² × length. Gravel volume = max(0, trench volume × gravel fill / 100 - pipe volume). Gravel weight = gravel volume × density. Fabric width = trench width + 2 × depth + overlap, and fabric area = fabric width × length.

Example calculations

Example 1: A 20 m run

A 20 m drain, 0.4 m wide and 0.6 m deep, has a trench volume of 4.8 m³. A 100 mm pipe takes about 0.16 m³, and an 80% gravel fill leaves about 3.68 m³ of gravel, or 5.89 tonnes at 1.6 t/m³. The fabric width is 1.9 m and the area is 38 m².

Example 2: A deeper 35 m run

A 35 m run, 0.5 m wide and 0.8 m deep, has 14.0 m³ of trench. A 110 mm pipe takes about 0.33 m³. At 85% fill and 1.7 t/m³, the gravel is about 11.57 m³, or 19.66 tonnes. The fabric width is 2.5 m and the area is 87.5 m².

Example 3: A short garden drain

A 10 m run, 0.3 m wide and 0.5 m deep, has 1.5 m³ of trench. An 80 mm pipe takes about 0.05 m³. At 70% fill and 1.5 t/m³, the gravel is about 1.00 m³, or 1.50 tonnes. The fabric width is 1.5 m and the area is 15 m².

What the result means

The gravel volume is the number to order, and the tonnage is what a supplier will usually quote. The pipe volume subtraction matters most on long runs with large pipe; for small garden drains it is a minor adjustment. The fabric width assumes the fabric wraps up both trench walls and overlaps at the top; check the roll width against that figure, because a narrow roll may need a different folding pattern or two passes. The estimate assumes a level trench and a constant cross-section. A real drain needs a fall toward the outlet, a properly sized outlet, and a filter fabric or geotextile appropriate to the soil.

Common mistakes

  • Ordering gravel by volume without checking the supplier's tonnage conversion.
  • Forgetting to subtract the pipe volume on long or large-diameter runs.
  • Using a trench that is too shallow for the frost line or the water table.
  • Skipping the filter fabric or using the wrong fabric for the soil.
  • Designing a drain with no fall or no outlet.
  • Ignoring local rules about where drainage water can be discharged.

Assumptions and limits

  • The trench has a constant rectangular cross-section over its length.
  • The gravel fill percentage is the share of the trench volume filled with gravel after the pipe.
  • The pipe runs the full length of the trench.
  • Gravel density is uniform and the supplier's tonnage matches the entered density.
  • Fabric overlap is a fixed extra width, not a percentage.
  • The estimate excludes outlets, clean-outs, connectors, and any excavation spoil removal.

Frequently asked questions

How much gravel do I need for a French drain?

It depends on the trench volume, the pipe size, and the fill percentage. A 20 m run at 0.4 m wide, 0.6 m deep, and 80% fill needs about 3.68 m³ of gravel after allowing for a 100 mm pipe.

What size pipe should a French drain use?

A 100 mm perforated pipe is common for residential drains, but the right size depends on the catchment, the soil, and the outlet. A larger pipe gives more capacity but does not fix a poor fall or a clogged filter.

Should the pipe be wrapped in fabric?

A filter sock or geotextile around the gravel or pipe helps keep fines out of the drain. The right choice depends on the soil. Fabric that is too fine can clog; fabric that is too coarse lets soil through.

How deep should a French drain be?

Deep enough to intercept the water and to reach a fall toward the outlet. The depth depends on the water table, the frost line, and the slope. A drainage designer or local guidance can help choose it.

Can I discharge the drain to the street?

Not always. Local rules often restrict where drainage water can go, especially if it carries sediment or enters a sanitary sewer. Check with the local authority before connecting the outlet.

Does the calculator include the outlet and clean-outs?

No. It covers the trench, gravel, pipe, and fabric. Add the outlet pipe, connectors, clean-outs, and any gravel for the outlet run separately.

Sources

This calculator is an educational planning tool, not financial, legal, insurance, medical, or professional advice. Results depend on the inputs and on rules that vary by place and provider. Confirm important decisions with a qualified professional and the relevant documents.

2026 update

How to use the professional output

This page is not just a formula box. The result is designed to be checked, compared, and taken away.

  • Professional worksheet. The result includes the inputs used, the method and scope, and a one-variable sensitivity check for finance calculators.
  • A/B scenarios. Save two input sets in the browser and compare the primary, secondary, and breakdown figures side by side.
  • Print / PDF and CSV. Print a branded worksheet, or export the year-by-year table when the calculator produces one.

The formulas and assumptions above still govern the number. The worksheet makes the estimate auditable; it does not make it a lender quote, tax return, or personalized advice.

Calccc Editorial Team · Updated 2026-11-19

Prepared by Calccc Editorial Team as an educational estimate. This page is not a licensed professional review and is not financial, medical, legal, or tax advice.

Editorial estimate prepared by the Calccc Editorial Team; not a licensed professional review.