Insulation R-Value Calculator

Enter the insulation thickness and its thermal conductivity. The calculator returns RSI in metric units, the equivalent imperial R-value, the U-value, and the thickness needed to reach a target RSI, plus a steady-state heat-flow estimate.

Updated 2026-11-18 Editorial estimate Calccc Editorial Team Free · No sign-up
mm
W/m·K

Also written as k or lambda. Mineral wool is often 0.032-0.040 W/m·K.

Advanced options
m²K/W

Used to find the thickness needed to reach a target.

°C

Used for the steady-state heat-flow estimate.

Scenarios A/BSave two input sets and compare the results. Stored only in this browser.
AEmpty
BEmpty

Your inputs stay in this browser. No account, no uploads.

Professional worksheet

Detailed schedule & assumptions

Inputs used, method, sensitivity, and any year-by-year table. The summary above stays compact; the audit lives here.

Professional worksheet

Inputs, scope, and sensitivity

Inputs used

Advanced inputs used

Method and scope

Result audit

MetricValue

What this calculator does

Thermal resistance measures how well a layer of insulation resists heat flow. In metric units it is RSI, in square metres kelvin per watt; in imperial units it is R-value, in square feet Fahrenheit hours per Btu. The two are proportional, and both are inversely related to the U-value, which describes heat flow per square metre per degree of temperature difference. Because insulation performance depends on thickness and conductivity, the same material can meet very different targets depending on how much is installed. This calculator converts between the measures and shows the thickness needed to reach a chosen target, which is useful when comparing products or checking a specification.

How to use it

  1. Enter the installed insulation thickness in millimetres.
  2. Enter the thermal conductivity from the product data sheet.
  3. Set a target RSI if you want to find the required thickness.
  4. Enter a temperature difference for the heat-flow estimate.
  5. Compare RSI, R-value, and U-value across products.

How it works

RSI = thickness in metres / thermal conductivity. Imperial R-value = RSI x 5.678. U-value = 1 / RSI. Thickness for a target = target RSI x conductivity x 1,000 mm. In the default case, 100 mm at 0.035 W/m·K gives RSI 2.86, R-value 16.2, and U-value 0.350 W/m²K.

Example calculations

Example 1: 100 mm of mineral wool at 0.035 W/m·K

The layer has RSI 2.86 and an imperial R-value of about 16.2. The U-value is 0.350 W/m²K, so a 20 °C difference drives about 7.0 W/m² through the insulation alone.

Example 2: 200 mm of a high-performance board at 0.022 W/m·K

Doubling the thickness and lowering the conductivity raises RSI to 9.09 and the imperial R-value to about 51.6. Reaching a target of 6.0 RSI needs about 132 mm of this material.

Example 3: 50 mm of a lower-performance material at 0.040 W/m·K

A thinner, more conductive layer gives only RSI 1.25 and R-value 7.1. To reach 2.0 RSI with this material would take about 80 mm.

What the result means

The calculation covers the insulation layer only. In a real wall or roof, surface resistances, timber or steel framing that bridges the insulation, air gaps, and moisture reduce the whole-assembly performance, often substantially. The U-value shown is therefore a best-case figure for the insulation itself, not the U-value of the completed element. Building codes set target R-values by climate zone and building element, and the right target depends on where you build and how the assembly is constructed. Use the calculator to compare products and check thickness, then confirm the assembly performance with a qualified designer.

Common mistakes

  • Comparing RSI and imperial R-values without converting.
  • Using the insulation R-value as the whole-wall R-value.
  • Ignoring thermal bridging through framing.
  • Assuming a product's conductivity is constant across temperatures.
  • Choosing thickness without checking the code target for the climate.

Assumptions and limits

  • The insulation layer is continuous and free of gaps.
  • Conductivity is constant across the temperature range.
  • Moisture and ageing do not change performance.
  • Framing, fixings, and surface resistances are excluded.
  • The target RSI is a design preference, not a code determination.

Frequently asked questions

What is the difference between RSI and R-value?

Both measure thermal resistance. RSI is the metric unit, m²K/W; R-value is the imperial unit, ft²·°F·h/Btu. One RSI equals about 5.678 units of imperial R-value, so the numbers are not interchangeable without conversion.

What is a U-value?

The U-value is the reciprocal of thermal resistance and describes heat flow per square metre per degree of temperature difference. A lower U-value means better insulation. It is usually quoted for a complete assembly, not just the insulation layer.

Why is my wall's R-value lower than the insulation's?

Framing, screws, and other penetrations bridge the insulation and conduct heat, and surface films add resistance. The whole-assembly R-value is therefore lower than the nominal insulation value, sometimes by 15 to 25 percent or more.

Does thickness alone determine performance?

No. Performance also depends on conductivity, installation quality, moisture, and ageing. A thicker lower-performance product can underperform a thinner high-performance one.

How do I find the target R-value?

Check the building code for your climate zone and the element being insulated. Codes commonly set minimum R-values for roofs, walls, and floors, and the targets differ significantly between cold and mild climates.

Can I use this for a multi-layer assembly?

Yes, by adding the RSI of each continuous layer. The calculator handles one layer at a time; sum the results for a multi-layer build-up, and account separately for bridging and surface resistances.

Sources

This calculator is an educational thermal estimate for the insulation layer only. It does not determine code compliance or whole-assembly performance. Confirm targets and construction details with a qualified designer.

2026 update

How to use the professional output

This page is not just a formula box. The result is designed to be checked, compared, and taken away.

  • Professional worksheet. The result includes the inputs used, the method and scope, and a one-variable sensitivity check for finance calculators.
  • A/B scenarios. Save two input sets in the browser and compare the primary, secondary, and breakdown figures side by side.
  • Print / PDF and CSV. Print a branded worksheet, or export the year-by-year table when the calculator produces one.

The formulas and assumptions above still govern the number. The worksheet makes the estimate auditable; it does not make it a lender quote, tax return, or personalized advice.

Calccc Editorial Team · Updated 2026-11-18

Prepared by Calccc Editorial Team as an educational estimate. This page is not a licensed professional review and is not financial, medical, legal, or tax advice.

Editorial estimate prepared by the Calccc Editorial Team; not a licensed professional review.