What this calculator does
A sump pump does not run continuously in normal conditions. It waits while water fills the basin, switches on, removes the water faster than it arrives, and switches off. The rhythm of that cycle tells you whether the pump and basin are matched to the water coming in. A pump that cycles every few seconds is usually oversized for the basin or has too little active volume, while a pump that never stops is undersized, blocked, or fighting a stuck float. This calculator estimates run time, fill time, cycle frequency, and daily duty from the basin geometry and flow rates. It is useful for diagnosing short cycling, for sizing a replacement basin, and for estimating how much run time a wet season adds. It assumes steady inflow and a pump curve that holds the entered flow at the actual discharge head.
How to use it
- Enter the total basin volume in litres.
- Enter the water volume when the float turns the pump on.
- Enter the water volume when the float turns it off.
- Enter the groundwater inflow rate in litres per minute.
- Enter the pump flow at the actual discharge head, not its open-flow rating.
- Check the cycles per hour and the duty cycle; short cycling suggests a mismatch.
How it works
Example calculations
Example 1: A well-matched setup
A 40 L basin with a 20 L active volume, 10 L/min inflow, and an 80 L/min pump runs for about 17 seconds and rests for 2 minutes. That is about 26 cycles per hour and a duty cycle near 12.5%, which is comfortable for a pump rated for continuous duty.
Example 2: Short cycling
The same pump with the float differential narrowed to 5 L runs for about 4 seconds every 30 seconds, or roughly 120 cycles per hour. The pump starts and stops constantly and will wear out faster. Widening the float differential or fitting a larger basin reduces the cycling without changing the pump.
Example 3: A pump that cannot keep up
If inflow rises to 90 L/min and the pump delivers 80 L/min, the net removal is negative and the pump runs continuously without clearing the basin. The calculator switches to a continuous-run warning. The fix is a larger pump, a second pump, or reducing the water reaching the pit, not a bigger float differential.
What the result means
Cycles per hour is the diagnostic number. Most pumps are happiest with a cycle that lasts several minutes rather than several seconds, because every start puts a surge through the motor and switch. A wide float differential, a larger basin, or a pump sized to run longer at a lower flow all reduce cycling. Inflow is the variable you can rarely control; during heavy rain or snowmelt it can be several times the summer rate. The estimate assumes steady inflow and a constant pump flow, so it is a snapshot for the conditions entered. Check the discharge line for a stuck check valve, a frozen or blocked outlet, or a clogged intake before concluding that the pump is failing.
Common mistakes
- Using the pump's open-flow rating instead of the flow at the real discharge head.
- Measuring the float-on and float-off levels in centimetres but entering litres.
- Ignoring a check valve that is stuck open, which lets water drain back and cycle the pump.
- Assuming inflow is constant through the year.
- Using a narrow float differential that causes short cycling.
- Blaming the pump for continuous running when the discharge is blocked.
Assumptions and limits
- Inflow and pump flow are steady during the cycle.
- The pump delivers the entered flow at the actual discharge head.
- The float-on volume is greater than the float-off volume.
- The basin geometry is horizontal and does not overflow during the cycle.
- There is no backflow through the check valve.
- The estimate excludes startup surge, motor heating, and controller behaviour.
Frequently asked questions
How often should a sump pump cycle?
There is no single rule, but a cycle measured in minutes is easier on the pump than one measured in seconds. A few cycles per hour in dry weather and more during heavy rain is normal; constant short cycling is not.
Why does my sump pump run every few seconds?
Usually because the active volume between the on and off floats is too small for the pump flow, or because water is draining back through a failed check valve. A wider float differential, a larger basin, or a new check valve usually fixes it.
What is a duty cycle?
It is the share of time the pump is running. A 12.5% duty cycle means the pump runs about 7.5 minutes out of every hour. Most residential pumps are rated for intermittent duty, so a high duty cycle during a storm is normal but sustained 100% running is not.
Can a sump pump be too powerful?
Yes. A pump that empties a small basin almost instantly will short cycle, which wears out the switch and motor. Matching the pump to the basin and the inflow matters more than buying the largest pump available.
How do I measure inflow?
Watch the basin fill with the pump off and time the rise against a known volume, or measure how long the pump takes to empty a known active volume. Repeat during wet weather, because the inflow in a storm is what matters for sizing.
Does the discharge head matter?
It matters a great deal. Pump flow falls as the height and pipe friction rise, so a pump rated at 80 L/min at open flow may deliver much less at the actual discharge height. Use the flow from the pump curve at the real head.
Sources
2026 update
How to use the professional output
This page is not just a formula box. The result is designed to be checked, compared, and taken away.
- Professional worksheet. The result includes the inputs used, the method and scope, and a one-variable sensitivity check for finance calculators.
- A/B scenarios. Save two input sets in the browser and compare the primary, secondary, and breakdown figures side by side.
- Print / PDF and CSV. Print a branded worksheet, or export the year-by-year table when the calculator produces one.
The formulas and assumptions above still govern the number. The worksheet makes the estimate auditable; it does not make it a lender quote, tax return, or personalized advice.